Technical guide, , by Green Automatica engineering team · 2 min read

Delta PLC, HMI and VFD programming in Kenya: DVP, AS series, DOP and C2000

Programming Delta DVP and AS series PLCs, DOP touch screens and VFD-E, MS300 and C2000 drives with ISPSoft, DOPSoft and VFDSoft.

Delta Electronics PLCs, HMIs and drives offer good value and are widely used on machines and pump controls in Kenya. We program, configure and troubleshoot Delta automation, and integrate it with other brands when a plant uses a mix of equipment.

Delta equipment we program and configure

EquipmentProduct familiesSoftware we use
PLCsDVP series (ES2, SS2, SE, EH3), AS seriesISPSoft, WPLSoft
HMIDOP-100 seriesDOPSoft
VFDsVFD-E, VFD-EL, ME300, MS300, C2000, CP2000VFDSoft, keypad

Networks and protocols: Modbus RTU and ASCII (RS-485), Modbus TCP, CANopen, EtherNet/IP on selected models.

What we do on Delta systems

  • PLC and HMI programs for small machines, pump controls and process skids
  • Drive setup for pumps and fans: PID, sleep mode and multi-pump control on CP2000
  • Modbus links between Delta drives, PLCs and HMIs, and third-party meters
  • Troubleshooting communication errors and drive fault codes

How we work on your Delta system

  1. Back up first. Before we touch anything, we upload and save the existing program, HMI project and drive parameters, so the machine can always be returned to how it was.
  2. Understand the process. We walk the machine with your operators and maintenance team, and agree in writing what the change or new program must do.
  3. Program and test offline. Logic, screens and drive settings are prepared and checked before site work, to keep downtime short.
  4. Commission on site. We test every input, output, interlock and alarm with your team, then run the machine under real load.
  5. Hand over properly. You receive the final, commented program, HMI project, drive parameter files, I/O list and drawings, plus training for your technicians.

Practical tips from our engineers

Use one Modbus network for drives and HMI

Delta HMIs can talk directly to Delta drives and PLCs over RS-485, which keeps small systems simple and cheap.

Set the drive for the load

The CP2000 is built for fans and pumps and the C2000 for general and heavy loads. Choosing and configuring the right one prevents trips on start.

Detailed Delta guides

Related services

See our PLC programming, SCADA and HMI and VFD and drives services, or read our overview of PLC, HMI and VFD programming for every major brand.

Frequently asked questions

Do you program Delta PLCs and HMIs?

Yes. We program DVP and AS series PLCs with ISPSoft and DOP HMIs with DOPSoft.

Can you configure Delta C2000 and MS300 drives?

Yes, including PID, multi-speed and Modbus control.

Keep reading

Tell us what you need to fix

Describe your site and the problem. An engineer reviews every request and replies with next steps, usually starting with a site assessment.